.. |br| raw:: html
.. role:: underline :class: underline .. _DCFSettings-label: ==================== How to DCF settings ==================== The dcf-file generated for the model requires checking by the structural engineer. The analysis can be generated with :py:func:`~viiapackage.viiaWorkflow._viia_analysis`. This function generates a default dc-file for VIIA. In this how-to guide it is explained what all the commands are and what commands VIIA requires. It states which items should be checked before running the analysis. Where there are options that are allowed to change (refer to the Basis of Design), an example is provided. This document is written for the NLTH process. The differences with the NLPO are collected in the section on NLPO. ------------------------- Threads for element loops ------------------------- Before any other diana module is invoked (this is before any call of `*`) the number of threads for the element loops should be specified. The number of threads for solving the element loops should be the same as those for solving the stiffness matrix (MAXTHR), for VIIA this is by default 4. This should be done with the next command: .. code-block:: NUMTHR 4 .. note:: **ONLY APPLY FOR COMMANDBOX**: * NUMTHR can only be specified when running an analysis with the command box. When running directly in DianaIE it's not possible to specify NUMTHR. .. _DCFSettingsInitialisation-label: -------------- Initialisation -------------- The following items need to be performed before the analysis can be performed. .. code-block:: *FILOS INITIA *INPUT *FORTRAN USE "E:\VIIA\usrifc.dll" .. note:: **CHECK BEFORE ANALYSIS**: * Check the above mentioned commands, they need to be added if you want to run in DIANA command box. * Check if the dll-file is provided on the mentioned location. **FILOS** |br| The central database during the analysis in DIANA is handled by FILOS, the FILe Organisation System, that is called the FILOS-file (ff). The FILOS-file is used through the complete analysis for the final element model. The FILOS-file is a binairy file format and cannot be moved to another computer, printed or viewed in a text editor. Most important command is the initialisation of the file. You can use another FILOS-file by removing the complete FILOS block from the file and to add the .ff in the command box when you initiate a new analysis. This can be useful if you want to perform an additional analysis after a first one (for example an eigenfrequency analysis). **INITIA** |br| Opens a new FILOS-file. **RESTOR** |br| With restore another FILOS-file can be read. This command can be used when the calculation needs to be continued with the last step (Syntax: RESTOR FILE=file.ff). See section :ref:`bugfixing_in_DIANA_for_DCF-label` for more information. **INPUT** |br| When nothing is defined in this command block, the input in the dat-file will be read. Specific files can be added in the dcf-file. **READ FILE="model.dat (not by default in VIIA)"** |br| Separate files with tables for 'MATERI' or 'GEOMET' can be read and redefine the previously read tables, or add these tables in case they were not present yet. **REMAKE FILE="test" (not by default in VIIA)** |br| With this command the dat-file is written, especially useful when multiple dat-files are combined. It makes it possible to check whether the correct tables are applied in the model. **FORTRAN** |br| **USE "E:\VIIA\usrifc.dll"** |br| The compiled library file needs to be provided. For windows OS this is an dll-file. The location must be provided. The dll-file is provided on all DIANA servers in E:\VIIA. This command is only required when a shallow foundation interface is applied. .. _DCFSettingsFirstPhase-label: ------------------------------- First phase - apply self weight ------------------------------- After the initialisation the self weight and the imposed loads that are present in the seismic situation are activated. The order of application of loads is important, when applying non-linear material models. Therefore the fem-model is setup in multiple phases. First phase block ----------------- The first phase activates the foundation element-sets are applied. .. code-block:: *PHASE LABEL="Activate foundation" BEGIN ACTIVE ELEMEN 'Element sets active in this phase' / REINFO 'Reinforcement sets active in this phase' / SUPPOR 'Support sets active in this phase' / TYINGS 'Tying sets active in this phase' / BEGIN AUTODE INTERF OFF BOUNDA OFF END AUTODE END ACTIVE **PHASE LABEL="Activate foundation"** |br| The phased analysis is initialised and a name is set for the phase. **BEGIN / END ACTIVE** |br| This block defines the items that are present in this phase in the fem-model. When nothing is set, it is expected that all the items are active. **ELEMEN / REINFO / SUPPOR / TYINGS** |br| These commands provide the respective sets with elements that are active in this phase. If no sets are present use the command NONE. First analysis block -------------------- The next part in the dcf-file provides the analysis of the weight of the current phase. This analysis is 'structural nonlinear'. .. code-block:: *NONLIN LABEL="Structural nonlinear 1" ***NONLIN LABEL="Structural nonlinear 1"** |br| The module structural nonlinear is started to perform a non-linear analysis on the current state of the model. .. _DCFSettingsEvaluateModel-label: Evaluate model ^^^^^^^^^^^^^^ Default settings for VIIA: .. code-block:: BEGIN MODEL BEGIN EVALUA CHECK OFF AVERAG ANGLE 0.349066 END EVALUA END MODEL **BEGIN / END MODEL** |br| Specifies the evaluation settings of the model for the analysis. **BEGIN / END EVALUA** |br| Specifies the evaluation settings of the elements. **CHECK OFF** |br| The extended test is not applied. **AVERAG ANGLE 0.349066** |br| Average nodal normals is applied with a tolerance angle of 20 degrees (0.349055 rad). Nonlinear effects ^^^^^^^^^^^^^^^^^ Default settings for VIIA: >>> BEGIN TYPE PHYSIC GEOMET BEGIN TRANSI METHOD NEWMAR BEGIN DYNAMI MASS BEGIN DAMPIN CONSIS RAYLEI OFF END DAMPIN RELBAC OFF END DYNAMI TIMEDE OFF END TRANSI END TYPE **BEGIN / END TYPE** |br| Specifies the type of analysis. **PHYSIC** |br| When applying this command the non-linear properties in the dat-file are used. If not specified further, all the non-linear properties in the dat-file are applied. **GEOMET** |br| When applying this command the geometrical non-linearity is taken into account defined by Lagrange formula. **BEGIN / END TRANSI** |br| This command sets the transient non-linear analysis. **METHOD NEWMAR** |br| The Newark integration scheme is used for the dynamic transient analysis. Parameter beta is 0.25 and gamma is 0.5. **BEGIN / END DYNAMI** |br| This command defines the dynamic analysis. A consistent mass matrix is used in the. The lumped mass matrix is not used because of the mesh refinement that is applied, which could lead to errors in the analysis. Consistent mass matrix is the default DIANA setting. **MASS** |br| Command to setup the mass matrix. Parameters are consistent mass matrix, including rotational terms and no distributed loads to dynamic mass. **BEGIN / END DAMPIN** |br| Command to setup the damping matrix. **CONSIS** |br| The consistent damping matrix is used. **RAYLEI OFF** |br| The Rayleigh damping is applied based on the initial stiffness matrix and is not recalculated each timestep. This is acceptable if the plasticity in the model is limited, see for more information note VIIA_QE_R376_N041. The Rayleigh damping values should be provided in the material definitions. **DAMPIN RAYLEI ON (Not applied in VIIA)** |br| The Rayleigh damping is calculated based on the actual stiffness matrix. Each timestep the dampings matrix is re-calculated. This option increases the calculation time. The Rayleigh damping values should be provided in the material definitions. **RELBAC ON (Not applied in VIIA)** |br| This command specifies the dynamic response caused by the base accelerations defined in the relative to base coordinate system. This does not provide good results in combination with the Hilber-Hughes-Taylor (HHT) integration-scheme. The Rayleigh damping is determined in another way, which seems not to be correct. DIANA-FEA is looking into this issue, for now it is advised not to apply this option. **TIMEDE OFF** |br| This command is not used in the analyses of VIIA. No time derivative effects. .. _DCFSettingsExecuteStart-label: Execute block - Start ^^^^^^^^^^^^^^^^^^^^^ Default settings for VIIA: >>> BEGIN EXECUT TEXT "Execute block B" BEGIN START BEGIN LOAD PREVIO OFF ADD LOADNR 1 END LOAD INITIA STRESS OFF BEGIN EXPLIC SIZES 0.5 0.5 ARCLEN OFF END EXPLIC END START .. note:: **CHECK BEFORE ANALYSIS**: * Check if the load number references the load-combination for the dead load. **BEGIN / END EXECUT / TEXT "Execute block B"** |br| This command block performs the load or time-steps. The dcf-file and the analysis block can contain multiple execute blocks. **BEGIN / END START** |br| The START command initialises the initial state of the model. The state before executing the first load or timestep. **BEGIN / END LOAD** |br| Defines the initial external loads. **PREVIO OFF** |br| No initial external loads are applied. **ADD LOADNR 0** |br| This command is used to define the applied external load. The load-combination of the dead load should be applied here. **INITIA STRESS OFF** |br| This command defines that the stresses are :underline:`not` automatically calculated linear elastic at the start of the execute block. **BEGIN / END EXPLIC** |br| Defines explicit steps. **SIZES 0.5 0.5** |br| This command defines the explicit steps that are used to apply the load. In the VIIA buildings, 2 steps should be sufficient. If problems with convergence are experienced, the step-size can be decreased (and multiple steps applied). **ARCLEN OFF** Arc length control is not used by default in VIIA. Execute block - Physical nonlinear options ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ Default settings for VIIA: >>> BEGIN PHYSIC CLEAR SUPPRE OFF DRAINE OFF LIQUEF OFF END PHYSIC **BEGIN / END PHYSIC** |br| Defines to overrule certain physical phenomena. **CLEAR** |br| Command to clear the displacement and rotation field at the start of this analysis. **SUPPRE OFF** |br| Command to suppress superposition, not applied in VIIA. **DRAINE OFF** |br| Command to for drained behaviour (of soil), not applied in VIIA. **LIQUEF OFF** |br| Command to applu liquefaction, not applied in VIIA. Execute block - Iteration method ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ The following part contains the iteration method settings and the convergence criteria. For VIIA the maximum tolerance is increased, so the analysis can continue longer so that it might find equilibrium. >>> BEGIN ITERAT MAXITE 10 METHOD NEWTON LINESE BEGIN CONVER BEGIN FORCE TOLCON 1.00000E-02 TOLABT 1.00000E+17 CONTIN END FORCE END CONVER END ITERAT **BEGIN/END ITERAT** |br| This command block defines the iteration process to find equilibrium for the applied load or timestep. **MAXITE 10** |br| The maximum number of iterations is depending on the iteration method. The following default values are suggested for the VIIA project. +-------------------------+----+ | Regular Newton Raphson | 10 | +-------------------------+----+ | Secant | 20 | +-------------------------+----+ | Linear stiffness | 20 | +-------------------------+----+ **METHOD NEWTON** |br| Specifies the applied iteration method. The Regular Newton-Raphson iteration method is applied by default in the VIIA project. But based in the convergence behaviour another iteration method can be used. This should be mentioned in the report, when reporting the analysis statistics. In the Regular Newton-Raphson method the stiffness matrix is evaluated in each iteration. The prediction for the next iteration is based on the last iteration, also when there was no equilibrium found that iteration. In general little number of iterations are required, but they relatively cost more analysis time. The method gives good convergence when the prediction is close to the final result. When this is not the vase, this method leads to divergence faster. After divergence it is possible to restart the calculation with a different iteration method applied. The Linear Stiffness or Constant Stiffness method can be selected. These methods in general require more iterations, but the time per iteration is less, because the stiffness matrix is not recalculated every iteration. Pay attention to allow for more iterations. **LINESE** |br| The line search algorithm scales the incremental displacements in the iteration process. A more stable convergence behaviour and faster iteration process can be found. **BEGIN/END CONVER** |br| In this command block the convergence criteria are specified. **SIMULT** |br| Command to apply multiple convergence criteria, both need to be satisfied. Currently this option is not used in VIIA. **BEGIN/END FORCE** |br| For the analysis parts that apply the self weight to the fem-model the default convergence criteria is set to be based on forces. **TOLCON 1.00000E-02** |br| The convergence criterium for analysis parts that apply the self weight to the FEM-model is set to 0.01, refer to note VIIA_QE_R376_N021. 1.0E-4 is the default setting in DIANA. **TOLABT 1E+17** |br| When this value is exceeded, the analysis is considered diverged. For VIIA we use a higher value than the default setting in DIANA. **CONTIN** |br| This command can be applied on two locations in the dcf-file. * Used as 'CONTIN' inside convergence loop, which is applied in VIIA: Analysis continues even if the convergence criteria are not satisfied when the maximum set iterations is reached. Each non-converging steps needs to be checked and listed in the final report. It must be assessed that the results of this step can be trusted. Multiple non-converge steps at a row is not allowed. * Used as 'CONTIN ON' at the beginning of iteration definition, which is **NOT** applied in VIIA: When a deformation process is relatively continuous, the previous displacement can be used to predict the next step, by ratio of the load increment. In non-continuous processes this leads to bad predictions. In the VIIA project this option is thus not used. **BEGIN/END DISPLA** |br| This sets the convergence criteria based on displacements. This is currently not applied in VIIA. **BEGIN/END ENERGY** |br| This sets the convergence criteria based on the energy criterium. The transient part is set to use this option, see the specific section for the transient part of this guide. Execute block - Logging information ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ Default settings of DIANA are used. Solver settings ^^^^^^^^^^^^^^^ Default settings for VIIA: >>> BEGIN SOLVE BEGIN PARDIS MAXTHR 4 SUBSTR OFF END PARDIS END SOLVE **MAXTHR 4** |br| The analysis is performed simultaneously on maximum of 4 threads. This setting has proven to be the most efficient value in the VIIA project on the VIIA servers. When this is not specified, the maximum available threads are used. Pay attention on the servers! When there are less threads available the analysis will delay. **SUBSTR OFF** |br| In VIIA substructuring is not applied. Output settings ^^^^^^^^^^^^^^^ See section on output for the structural assessment, see :ref:`Output_structural-label`. Or see section on output for the geotechnical assessment, see :ref:`Output_geotechnical-label`. --------------------------- Next phases for self weight --------------------------- This process is repeated for the next phase in which a part of the building is added to the fem-model. .. code-block:: *PHASE LABEL="Activate building layer N0" BEGIN ACTIVE ELEMEN Elementensets active in this phase REINFO Reinforcementsets active in this phase SUPPOR Supportsets active in this phase TYINGS Tyingsets active in this phase BEGIN AUTODE INTERF OFF BOUNDA OFF END AUTODE END ACTIVE The analysis block is setup in a similar way. .. code-block:: *NONLIN LABEL="Structural nonlinear 1" BEGIN MODEL BEGIN EVALUA CHECK OFF AVERAG ANGLE 0.349066 END EVALUA END MODEL BEGIN TYPE PHYSIC GEOMET BEGIN TRANSI METHOD NEWMAR BEGIN DYNAMI MASS BEGIN DAMPIN CONSIS RAYLEI OFF END DAMPIN RELBAC OFF END DYNAMI TIMEDE OFF END TRANSI END TYPE BEGIN EXECUT TEXT "Execute block B" BEGIN START LOAD ADD OFF INITIA STRESS OFF BEGIN EXPLIC SIZES 0.5 0.5 ARCLEN OFF END EXPLIC END START BEGIN PHYSIC CLEAR SUPPRE OFF DRAINE OFF LIQUEF OFF END PHYSIC BEGIN ITERAT METHOD NEWTON LINESE BEGIN CONVER BEGIN FORCE TOLCON 1.00000E-02 TOLABT 1.00000E+17 CONTIN END FORCE DISPLA OFF ENERGY OFF RESIDU OFF END CONVER END ITERAT END EXECUT BEGIN SOLVE BEGIN PARDIS MAXTHR 4 SUBSTR OFF END PARDIS END SOLVE This process is repeated until the fem-model is completely setup. ---------------- Seismic analysis ---------------- In the last analysis block of the last phase, two execute blocks are required create the transient analysis. .. code-block:: BEGIN EXECUT TEXT "Execute block E" BEGIN START LOAD ADD OFF INITIA STRESS OFF STEPS EXPLIC SIZES 1.0 END START > Physic and iteration procedure as previous END EXECUT BEGIN EXECUT TEXT "Execute block F" TIME STEPS EXPLIC SIZES 0.01(1050) BEGIN PHYSIC CLEAR SUPPRE OFF DRAINE OFF LIQUEF OFF END PHYSIC BEGIN ITERAT MAXITE 10 METHOD NEWTON LINESE BEGIN CONVER FORCE OFF DISPLA OFF BEGIN ENERGY TOLCON 1.00000E-04 TOLABT 1.00000E+17 CONTIN END ENERGY END CONVER END ITERAT END EXECUT BEGIN SOLVE BEGIN PARDIS MAXTHR 4 SUBSTR OFF END PARDIS END SOLVE > Output *END .. note:: **CHECK BEFORE ANALYSIS**: * Check if the signal length is equal to the signal and post-seismic part. Only commands that were not present in the self-weight steps are described: **STEPS EXPLIC SIZES 0.01(1000)** |br| In VIIA the step-size is default set to 0.01s. Check the length of the signal to determine the number of steps, and include some steps to calculate the post-seimic values. **SAVE 10-1000(10) (Not applied in VIIA by default)** |br| This command saves every 10 time-steps the filos-file. When divergence occurs, the analysis can be restarted. It is advised to apply the following commands in a batch file, to reduce the disk size demand. .. code-block:: @echo off :begin IF EXIST diana20.ff del /F diana10.ff IF EXIST diana30.ff del /F diana20.ff IF EXIST diana40.ff del /F diana30.ff etc. goto begin **END** |br| End statement of the dcf-file. .. _output_structural-label: ------------------------------------ Output for the structural assessment ------------------------------------ When creating the dcf-file you need to know upfront which output items you required for the assessment of the building. For the VIIA project, we have derived a default dcf-file. This is based on all previous and finalised buildings, as well as on the client demands. The amount of requested output items is on the other hand slowing the calculation. The suggested default dcf-file balances these aspects. The following result items in the analysis are set by default and in this section the use and reason for these output items are discussed. Next to it, there is also a warning what to check before running the calculation. 1. Displacements and relative displacements of the building elements. 2. Accelerations of reference points. 3. Cracking of masonry (crack width), including status parameters. As well as for non-linear modelled concrete. 4. Forces in the linear connections (and l2-measures). 5. Residual forces (mainly for bug-fixing). 6. Section forces (shear forces) of elements that are modelled with linear elastic material models. 7. Relative displacements of non-linear connections. 8. Strains of non-linear reinforcement steel. The following table contains the description of the commands in the output-blocks. The specific output items are discussed in detail in the following sections. +-----------------+--------------------------------------------------------------------+ | DCF-COMMAND | Description what is does in DIANA and how VIIA uses it | +=================+====================================================================+ | BEGIN OUTPUT | Start of single output block item. | +-----------------+--------------------------------------------------------------------+ | TEXT | Name of the output. | +-----------------+--------------------------------------------------------------------+ | BINARY | Export type DIANA native (dnb-file). | +-----------------+--------------------------------------------------------------------+ | TABULATED | Export type tabulated file (tb-file). | +-----------------+--------------------------------------------------------------------+ | LAYOUT LINPAG 0 | Selections for lay-out of tabulated file, syntax example for | | | layout without page numbers (to facilitate reading tb-files in | | | scripts). | +-----------------+--------------------------------------------------------------------+ | FILE | Name of the output file. | +-----------------+--------------------------------------------------------------------+ | SELECT STEPS | Select the steps for the output. LAST = last step, MAX = maximum | | | value of all previous steps, MIN = maximum value of all previous | | | steps. Example string: 1-10 11-1050(50) means output is requested | | | for all steps from 1 to 11 and step 12, 62 etc. until 1050 is | | | reached. | +-----------------+--------------------------------------------------------------------+ | SELECT ELEMEN | Select the elements for the output (element output only). | +-----------------+--------------------------------------------------------------------+ | SELECT NODES | Select the nodes for the output (nodal output only). | +-----------------+--------------------------------------------------------------------+ | END OUTPUT | End of output block | +-----------------+--------------------------------------------------------------------+ The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_block.png :align: center In VIIA analysis the following output blocks are generated: +-------------------------------------------------------------------------------------------------+ | Static analysis | +==================+==============================================================================+ | OUTPUT_STATIC-NL | Nodal/element results for the entire building (DIANA native). | +------------------+------------------------------------------------------------------------------+ +-------------------------------------------------------------------------------------------------+ | Nonlinear dynamic analysis | +==================+==============================================================================+ | OUTPUT_1A_MAX | Maximum nodal/element results for the entire building (DIANA native). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_1B_MIN | Minimum nodal/element results for the entire building (DIANA native). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_1C | More steps during intens part of signal, maximum and minimum nodal/element | | | results for the entire building (DIANA native). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_2 | Displacement results for reference nodes of the walls (tabulated). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_3 | Nodes to plot acceleration graph (tabulated). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_4 | Minimum and maximum stress results for linear structural elements | | | (DIANA native). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_4A | Minimum and maximum stress results for linear structural elements | | | (tabulated), for making plot from python. | +------------------+------------------------------------------------------------------------------+ | OUTPUT_4B | Stress results for linear structural interfaces (tabulated), used for tables | | | in the report. | +------------------+------------------------------------------------------------------------------+ | OUTPUT_5A | Boundary interface tractions for shallow foundation (tabulated). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_5B | Nodal element forces for piles (tabulated). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_GEO1 | Minimum and maximum element results for the shallow foundation (DIANA | | | native). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_GEO2 | Element results for the shallow foundation of the last step, or the | | | post-seismic situation (DIANA native). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_GEO_REF | Nodal/element results for reference nodes in shallow foundation (tabulated). | +------------------+------------------------------------------------------------------------------+ | OUTPUT_MOVIE | Displacement results for the entire model to make a movie (DIANA native) | +------------------+------------------------------------------------------------------------------+ Block 1 - General ----------------- The output blocks 1 contain the general result items of the model. The output block 1A collects the maximum values up to the selected steps of the signal. The syntax for the dcf-file is: .. code-block:: BEGIN OUTPUT TEXT OUTPUT_1A_MAX BINARY FILE "SXXX_OUTPUT_1A_MAX" SELECT BASNOD 0 SELECT NODES 'nodes building' / SELECT ELEMEN 'elements building' / SELECT STEPS 10-100(10) 101-1000(50) LAST / MAX DISPLA TOTAL TRANSL GLOBAL RELATI ON DISPLA TOTAL TRANSL GLOBAL STRAIN CRKWDT GREEN PRINCI INTPNT STRESS TOTAL CAUCHY PRINCI INTPNT STRESS TOTAL TRACTI LOCAL INTPNT STRAIN TOTAL TRACTI LOCAL INTPNT FORCE REACTI TRANSL GLOBAL FORCE RESIDU TRANSL GLOBAL END OUTPUT .. note:: **CHECK BEFORE ANALYSIS**: * All elements en nodes of building and connections should be selected. * Decide if output-block 1C is required. * Check if the signal length is correctly applied. * Check if base node is correctly selected. The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_1A_max.png :align: center Output block 1B collects the minimum values of the output items up to the selected steps in the signal. .. code-block:: BEGIN OUTPUT TEXT OUTPUT_1B_MIN BINARY FILE "SXXX_OUTPUT_1B_MIN" SELECT BASNOD 0 SELECT NODES 'nodes building' / SELECT ELEMEN 'elements building' / SELECT STEPS 10-100(10) 101-1000(50) LAST / MIN DISPLA TOTAL TRANSL GLOBAL RELATI ON STRAIN CRKWDT GREEN PRINCI INTPNT STRESS TOTAL CAUCHY PRINCI INTPNT STRESS TOTAL TRACTI LOCAL INTPNT STRAIN TOTAL TRACTI LOCAL INTPNT FORCE REACTI TRANSL GLOBAL FORCE RESIDU TRANSL GLOBAL STATUS EMASON END OUTPUT The nodes and the elements selected should contain only the nodes and elements of the building. For element output the results are assessed only in the integration points (INTPNT). By providing the base node the displacements and accelerations will be retrieved compared to that point. For VIIA this point should be selected on the foundation strip. The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_1B_min.png :align: center To get more data from the more intense parts of the signal the output-block 1C could be added to the dcf-file. This block is not added by default to improve for the analysis time. .. code-block:: BEGIN OUTPUT TEXT OUTPUT_1C BINARY FILE "SXXX_OUTPUT_1C" SELECT BASNOD 0 SELECT NODES 'nodes building' / SELECT ELEMEN 'elements building' / SELECT STEPS 10- 1-5 50-400(5) LAST DISPLA TOTAL TRANSL GLOBAL RELATI ON DISPLA TOTAL TRANSL GLOBAL STRAIN CRKWDT GREEN PRINCI INTPNT STRESS TOTAL CAUCHY PRINCI INTPNT STRESS TOTAL TRACTI LOCAL INTPNT STRAIN TOTAL TRACTI LOCAL INTPNT FORCE REACTI TRANSL GLOBAL FORCE RESIDU TRANSL GLOBAL END OUTPUT The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_1C.png :align: center Block 2 - Wall displacements ---------------------------- To check the in-plane and out-of-plane behaviour of the walls the displacements and accelerations are collected on bottom, center and top of the wall for all time-steps and all walls in the fem-model. This output is written in a tabulated file to provide for automated result handling. Also for the assessment of the interstorey drift the bottom and top points of the walls are used. .. code-block:: BEGIN OUTPUT TEXT OUTPUT_2 TABULA FILE "SXXX_OUTPUT_2" LAYOUT LINPAG 0 SELECT NODES 'nodes of walls (bottom, mid and top)' / SELECT ELEMEN NONE / SELECT STEPS ALL / DISPLA TOTAL TRANSL GLOBAL X Y Z END OUTPUT The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_2.png :align: center Block 3 - Acceleration graph ---------------------------- The output-block 3 is to collect the nodes for the acceleration plots. .. code-block:: BEGIN OUTPUT TEXT OUTPUT_3 TABULA FILE "SXXX_OUTPUT_3" LAYOUT LINPAG 0 SELECT NODES 'nodes of reference points' / SELECT ELEMEN NONE / SELECT STEPS ALL / DISPLA TOTAL TRANSL GLOBAL X Y Z END OUTPUT The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_3.png :align: center :scale: 100% Block 4 - Linear-elastic modelled elements ------------------------------------------ Some elements in the fem-model are modelled with linear-elastic material models. These elements need to be checked if they comply to the capacity of these materials. When the element is a strengthening measure the results are added to report for a next phase. It is important to check whether these forces allow for a proper design. The shallow foundation boundary interface elements are not included in this output-block. Compliance check is performed on the minimum and maximum values of the complete analysis (last step). .. code-block:: BEGIN OUTPUT TEXT OUTPUT_4 BINARY FILE "SXXX_OUTPUT_4" SELECT ELEMEN 'elements for linear elastic elements' / SELECT STEPS LAST / MIN MAX STRESS TOTAL DISFOR LOCAL XX YY ZZ XY YZ ZX STRESS TOTAL DISMOM LOCAL STRESS TOTAL CAUCHY LOCAL INTPNT XX YY ZZ XY YZ ZX STRESS TOTAL FORCE LOCAL X Y Z STRESS TOTAL MOMENT LOCAL STRESS TOTAL CAUCHY VONMIS INTPNT STRAIN TOTAL GREEN LOCAL INTPNT END OUTPUT The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_4.png :align: center Output-block 4B is generated for linear structural interfaces in tabulated format. This output is used for the result handling on shear forces in the linear connections and L2-measures in the model. .. code-block:: BEGIN OUTPUT TEXT OUTPUT_4B TABULA FILE "SXXX_OUTPUT_4B" SELECT NODES 'nodes of linear structural interfaces' / SELECT ELEMEN 'elements of linear structural interfaces' / SELECT STEPS ALL STRAIN TOTAL TRACTI LOCAL INTPNT STRESS TOTAL TRACTI LOCAL INTPNT END OUTPUT Block 5 - Base shear -------------------- The base shear is required to plot in the final report. It gives insight in the building and can be used to check if the analysis is performed correctly. The required type of output depends on the type of foundation. Refer to the section of shallow foundations or pile foundations. In case of mixed foundation both output blocks should be applied. Shallow foundation ^^^^^^^^^^^^^^^^^^ The base shear is calculated based on the stresses in the shallow foundation interface. The local axes should have been aligned. The output is requested for all time-steps. This output is also used to provide information to the geotechnical engineer (see next section). .. code-block:: BEGIN OUTPUT TEXT OUTPUT_5A TABULA FILE "SXXX_OUTPUT_5A" LAYOUT LINPAG 0 SELECT ELEMEN 'elements shallow foundation interfaces' / SELECT STEPS ALL STRESS TOTAL TRACTI LOCAL CENTER END OUTPUT The result handling is automated for the default tabulated output. .. note:: **CHECK BEFORE ANALYSIS**: * Check if axes of shallow foundation interface are aligned. * Check if all elements of the shallow foundation interface are selected. The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_5A.png :align: center Pile foundation ^^^^^^^^^^^^^^^ The base shear is calculated based on the section forces of the beam element representing the foundation pile. The nodal force is collected for the beam element and the bottom node of it. This output is also used to provide information to the geotechnical engineer (see next section). .. code-block:: BEGIN OUTPUT TEXT OUTPUT_5B TABULA FILE "SXXX_OUTPUT_5B" LAYOUT LINPAG 0 SELECT NODES 'Nodes at the bottom of the beam elements representing the foundation piles in the fem-model' / SELECT ELEMEN 'Elements of the beam elements representing the foundation piles in the fem-model' / SELECT STEPS ALL NODFOR TOTAL TRANSL GLOBAL X Y Z END OUTPUT The result handling is automated for the default tabulated output. .. note:: **CHECK BEFORE ANALYSIS**: * Check if all piles are selected. * Check if only bottom nodes of beam elements are selected. The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_5B.png :align: center Block - Movie ------------- For visualisation of the building behaviour the movie output items are requested. .. code-block:: BEGIN OUTPUT TEXT OUTPUT_MOVIE BINARY FILE "SXXX_OUTPUT_MOVIE" SELECT NODES 'complete model' / SELECT STEPS ALL DISPLA TOTAL TRANSL GLOBAL X Y Z END OUTPUT The result handling is automated for the default tabulated output. .. note:: **CHECK BEFORE ANALYSIS**: * Check if only nodes of the complete model are selected. The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_MOVIE.png :align: center .. _output_geotechnical-label: -------------------------------------- Output for the geotechnical assessment -------------------------------------- This section describes the output that is required by the geotechnical advisor for the assessment of the foundation. Shallow foundation ------------------ For the flexbase shallow foundation analyses the following output items are requested: Stresses in normal and 2 shear directions in the interface elements between foundation strip and soil (base): * Maximum stress values all time-steps of transient analysis * Minimum stress value all time-steps of transient analysis * Stress values after applying all loads in static situation existing building * Stress values after applying all loads in static situation strengthened building * Stress values at the post-seismic situation (last timestep) of strengthened building To determine the last step of the analysis (the post-seismic situation), the acceleration of the base (soil) should be zero. By default we add 0.5 seconds to the signal, this assumption needs to be checked after the analysis. For the output items related to the maximum and minimum stresses in the transient analysis the syntax in the dcf-file should be: .. code-block:: BEGIN OUTPUT TEXT OUTPUT_GEO1 BINARY FILE "SXXX_GEO1" SELECT STEPS LAST / MIN MAX SELECT ELEMEN 'elementensets shallow foundation interfaces' / STRESS TOTAL TRACTI LOCAL INTPNT STRAIN TOTAL TRACTI LOCAL INTPNT END OUTPUT The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_GEO1.png :align: center For the output items related to the post-seismic stresses in the transient analysis the syntax in the dcf-file should be: .. code-block:: BEGIN OUTPUT TEXT OUTPUT_GEO2 BINARY FILE "SXXX_GEO2" SELECT STEPS LAST SELECT ELEMEN 'elementensets shallow foundation interfaces' / STRESS TOTAL TRACTI LOCAL INTPNT STRAIN TOTAL TRACTI LOCAL INTPNT END OUTPUT .. note:: **CHECK BEFORE ANALYSIS**: * Elements should contain the shallow foundation interface only. The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_GEO2.png :align: center Additional information for the geotechnical advisor is retrieved from the output block 5. More information will be added here. The output items in GEO1 and GEO2 are used to generate a picture with the strains and stresses in the shallow foundation interface. These pictures should be assessed for unexpected behaviour of the interface. It might help to allocate deficiencies in the foundation of the building. The picture should be sent to the geotechnical advisorm, but are not required to be added in the report. .. figure:: _static/howto_dcf/GEO1_MIN_Z.png :align: center Figure - Example picture of the minimum normal stress in the shallow foundation in [kN/m2]. .. note:: Examples of unexpected behaviour: * Tensile stresses in the shallow foundation interface. * Compressive stresses exceeding the provided bearing capacity. * Excessive shear stresses in x- or y-direction. * The pictures could also demonstrate that the axes of the elements are not correctly alligned. Reference output ^^^^^^^^^^^^^^^^ It could be required to verify the behaviour of the shallow foundation interface. Therefore by default reference elements are selected randomly (but if the geotechnical advisor requests a specific point, that should be added in this output-item). This element is assessed in all time-steps and can be used to generate stress-strain diagrams to provide insight in the non-linear behaviour. .. code-block:: BEGIN OUTPUT TEXT OUTPUT_GEO_REF TABULATED FILE "SXXX_GEO_REF" LAYOUT LINPAG 0 SELECT STEPS ALL SELECT ELEMEN 'list of (random) elements shallow foundation interfaces' / STRESS TOTAL TRACTI LOCAL INTPNT STRAIN TOTAL TRACTI LOCAL INTPNT END OUTPUT The dcf commands can be checked in the DIANA GUI: .. figure:: _static/howto_dcf/output_GEO_REF.png :align: center Pile foundation --------------- For the flexbase pile foundation analyses the following output items are requested: Pile forces in normal and 2 shear directions in the beam element representing the pile: * Maximum force values over all time-steps of transient analysis * Minimum force values over all time-steps of transient analysis * Pile force values after applying all loads in static situation existing building * Pile force values after applying all loads in static situation strengthened building * Pile force values at the post-seismic situation (last timestep) of strengthened building To determine the last step of the analysis (the post-seismic situation), the acceleration of the base (soil) should be zero. By default we add 0.5 seconds to the signal, this assumption needs to be checked after the analysis. All the required information is already present in output block 5. Therefore no additional output is required in the dcf-file. More information will be added here. .. _bugfixing_in_DIANA_for_DCF-label: -------------------------- Bugfixing in DIANA for DCF -------------------------- Resume the calculation from last converged step ----------------------------------------------- It is possible in DIANA to resume the analysis after a non-converged step or a forced stopped analysis. Then it is not required to restart the whole calculation to retrieve the load-history for instance. Resuming the analysis can be done from the last converged and saved time or load step. Therefore the command SAVE CONVER should have been added to the analysis. Saving the converged time or load-step does however decreases the analysis time. That is why it is not set by default for VIIA project. Before restart the dcf-file must be updated in locations: #. Remove the FILOS INITIA command (or replace with FILOS UNLOCK in case of a forced stopped analysis). #. Add MODEL OFF and TYPE OFF at the start of the dcf-file. #. Previously performed execute blocks should be removed. #. Add RESTORE with the number of the last converged step between BEGIN STEPS and END STEPS. #. Add APPEND in the output blocks. For example assume that step 78 is the last converged step, then restart can be performed with: >>> BEGIN TIME BEGIN STEPS EXPLIC SIZES 0.0 0.01(1050) RESTORE 78 SAVE CONVER END STEPS END TIME Eigenvalue analysis ------------------- Before starting the analysis, or during the analysis, an eigenvalue analysis can be performed based on the last converged step. This might give insight in the weak parts of the building during the calculation. Remember when the analysis is started with a saved filos file, you do not have to initiate a new one. See the following example: .. code-block:: *EIGEN LABEL="Structural eigenvalue" MODEL OFF TYPE FREEVI STIFFN NONLIN STRESS PHASE BEGIN EXECUT METHOD FEAST NMODES 200 FMIN 2 FMAX 20 EMIN 0 EMAX 1 END EXECUT BEGIN OUTPUT TEXT "Output eigenvalue analysis" BINARY SELECT MODES ALL / END OUTPUT *END Adaptive stepsize ----------------- Adaptive load increments applies an automated reduction of step-size for a non-converging step. Advantage of this procedure is that instead of continuing with the analysis in the wrong direction and resulting in divergence, it could solve a numerical issue with smaller steps and continue through the non-linear point. The following syntax can be used: .. code-block:: BEGIN EXECUT TEXT "Seismic non-linear" BEGIN TIME BEGIN STEPS BEGIN AUTOMA SIZES 10 MAXSIZ 1e-3 MINSIZ 1e-10 END AUTOMA SAVE 100-2010(100) END STEPS END TIME In the example the total step size depends on the signal length of 10 seconds. For the maximum step-size it is advised to use the normal step size (10 ms). Change iteration procedure during the analysis ---------------------------------------------- When the SWITCH command is applied in the iteration proces the analysis will change iteration method after any diverging, non-converging or error. First regular Newton Raphson is applied, then it will be switched to Secant and then to linear. Drawback is that is does not switch back to the original iteration method after convergence in the next step. The maximum number of iterations is not adjusted when switching. .. code-block:: BEGIN ITERAT MAXITE 20 METHOD NEWTON SWITCH BEGIN CONVER FORCE OFF DISPLA OFF BEGIN ENERGY TOLABT 1000 CONTIN END ENERGY END CONVER END ITERAT .. warning:: Because of unclear results, it is not allowed in VIIA to use this procedure in analyses that are used for the assessment of the object. .. _NLPODCFSettings-label: -------------- NLPO specifics -------------- This section contains explanation of the items in the dcf-file that are specific for the NLPO procedure. If the setting is not different then the procedure for NLTH, refer to the sections above. Initialisation, see :ref:`DCFSettingsInitialisation-label`. Phasing, see :ref:`DCFSettingsFirstPhase-label`. First analysis block -------------------- The next part in the dcf-file provides the analysis of the weight of the current phase. This analysis is 'structural nonlinear'. .. code-block:: *EIGEN LABEL="Structural eigenvalue" ***EIGEN LABEL="Structural eigenvalue"** |br| The module eigen is started to perform an eigen value analysis on the current state of the model. Evaluate model, see :ref:`DCFSettingsEvaluateModel-label`. Nonlinear effects ^^^^^^^^^^^^^^^^^ Default settings for VIIA: >>> TYPE FREEVI STIFFN LINEAR STRESS OFF Execute block ^^^^^^^^^^^^^ Default settings for VIIA: .. code-block:: BEGIN EXECUT PARDIS MAXTHR 4 NMODES 20 FSHIFT 0 MAXITE 30 .. note:: **CHECK BEFORE ANALYSIS**: * Check if the number of eigenmodes to contain the dominant eigen frequency from A7 analysis. **MAXTHR 4** |br| The analysis is performed simultaneously on maximum of 4 threads. This setting has proven to be the most efficient value in the VIIA project on the VIIA servers. When this is not specified, the maximum available threads are used. Pay attention on the servers! When there are less threads available the analysis will delay. **NMODES 20** |br| Select the number of eigenfrequencies such that the dominant eigen frequency is present (Based on the A7 analysis). **MAXITE 30** |br| Maximum number of iterations is set to 30. Output settings ^^^^^^^^^^^^^^^ The output block contain the output for the eigen frequency analysis. These result items are the expressed as a global translational total displacement, or the shapes of the eigenmode. The displacements are not real values but a relative displacement, showing the shape of the mode. .. figure:: _static/howto_dcf/output_NLPO_EIGEN.png :align: center Pushover analysis block ----------------------- The next part in the dcf-file provides the analysis of the pushover. This analysis is 'structural nonlinear'. .. code-block:: *NONLIN LABEL="Nonlinear Pushover" Evaluate model, see :ref:`DCFSettingsEvaluateModel-label`. Nonlinear effects ^^^^^^^^^^^^^^^^^ Compared to the NLTH the setting for transient nonlinear effects is switched off. Default settings for VIIA: .. code-block:: BEGIN TYPE BEGIN GEOMET NCLOAD OFF NLPREB OFF END GEOMET TRANSI OFF END TYPE **BEGIN / END TYPE** |br| Specifies the type of analysis. **GEOMET** |br| When applying this command the geometrical non-linearity is taken into account defined by Lagrange formula. **NCLOAD OFF** |br| Option for non-conservative load-cases is not used for VIIA. **NLPREB OFF** |br| Option for subsequent Euler perturbation analysis with pre-buckling nonlinearity is not used for VIIA. Execute block - SW ^^^^^^^^^^^^^^^^^^^^^ Default settings for VIIA: .. code-block:: BEGIN EXECUT TEXT SW BEGIN LOAD LOADNR 1 BEGIN STEPS BEGIN EXPLIC SIZES 0.5 0.5 ARCLEN OFF END EXPLIC END STEPS END LOAD Load steps, see :ref:`DCFSettingsExecuteStart-label`. .. code-block:: BEGIN ITERAT METHOD NEWTON LINESE OFF BEGIN CONVER SIMULT ON BEGIN FORCE TOLCON 0.001 TOLABT 1e+17 CONTIN END FORCE BEGIN DISPLA TOLCON 0.001 TOLABT 1e+17 CONTIN END DISPLA END CONVER END ITERAT END EXECUT